Solved 4) Complete the following table for refrigerant134a
Complete This Table For Refrigerant-134A. Use data from the steam tables. Properties of saturated r134a, presented at regular intervals of temperature specific volume (m3/kg) specific internal energy (kj/kg) specific enthalpy.
This is the normal domestic refrigerator having refrigerant 180 grams placed in the system. State 1:t = 10 °c, p = 300 kpa , from table a 12 (saturated refrigerant 134a pressure table), for p = 280 kpa, tsat = 1.25 °c, for p = 320 kpa, tsat = 2.46 °c, hence, for p = 300 kpa, tsat = Use data from the steam tables. Tables a−11 through a−13 are generated using the engineering equation solver (ees) software developed by s. Web complete the following table for refrigerant 134a ( 16 marks). Properties of saturated r134a, presented at regular intervals of temperature specific volume (m3/kg) specific internal energy (kj/kg) specific enthalpy. Web table reading taken from the process of r134a refrigerant placed within the experimental setup. Т, °f p, psia phase description h, btu/lbm х 80 78 15 0.6 10 70 180 129.46 110 1.0 this problem has been solved! You'll get a detailed solution from a subject matter expert that helps you learn core concepts. Use data from the steam tables.
Note the reading of compressor water, mechanical device outlet condenser outlet, evaporator temperature pressure & of varied parameters within the setup. This is the normal domestic refrigerator having refrigerant 180 grams placed in the system. Tables a−11 through a−13 are generated using the engineering equation solver (ees) software developed by s. State 1:t = 10 °c, p = 300 kpa , from table a 12 (saturated refrigerant 134a pressure table), for p = 280 kpa, tsat = 1.25 °c, for p = 320 kpa, tsat = 2.46 °c, hence, for p = 300 kpa, tsat = State 1:t = 8 °c, p = 320 kpa , from table a 12 (saturated refrigerant 134a pressure table), for p = 320 kpa, tsat = 2.46 °c, as t < tsat , hence, state 1 is compressed (subcooled) liquid, hence, conditions are nearly the same as those at saturated liquid corresponding to t = 8 °c. Web complete the following table for refrigerant 134a ( 16 marks). You'll get a detailed solution from a subject matter expert that helps you learn core concepts. Note the reading of compressor water, mechanical device outlet condenser outlet, evaporator temperature pressure & of varied parameters within the setup. Т, °f p, psia phase description h, btu/lbm х 80 78 15 0.6 10 70 180 129.46 110 1.0 this problem has been solved! There is currently serious consideration of replacing it with r744 (carbon dioxide) in refrigeration and heat pump applications. Properties of saturated r134a, presented at regular intervals of temperature specific volume (m3/kg) specific internal energy (kj/kg) specific enthalpy.